5 Alternating Blinks (SFP) / ##356 (MFP) - ASF Cam Sensor Error

SFP: PIXMA iP3000/4000/4000R/5000/6000D/8500

MFP: PIXMA MP750/760/780

DESCRIPTION: 5 Alternating Blinks (SFP) / ##356 (MFP) - ASF Cam Sensor Error

SOLUTION(S): Adjust the Screws & Main Case Unit

Movement (i.e. from shipping) may cause the plastic guide to move away from the chassis. When this

occurs, the gears cannot rotate properly causing a grinding noise and 5 alternating blinks (SFP) or ##356

(MFP) - ASF Cam Sensor Error.